Looking for the Caretaker VinylCare Floor Fitting in Dark Blue?
These collars are installed on the outside of a 2″ Schedule 40 PVC Riser Pipe. The Riser Pipe is cut 1 7/8″ below the concrete prior to gluing. Use only PVC:ABS glue to install the collars. Primer is only required on the PVC Riser Pipe, DO NOT PRIMER THE VINYL COLLARS.
Installation For Vinyl Liner Pools:
POOL LINER MUST BE IN FINAL POSITION BEFORE INSTALLING COLLARS AND CLEANING HEADS
1. Press locking ring firmly into place in groove on collar fitting. Installation Tip: Turn collar upside down and use as a tool to press ring into place!
2. Use a razor knife to cut liner inside the locking ring, leaving at least a ¼ in. (0.6 cm) edge around the ring perimeter.
3. Tighten the collar into the collar fitting, turning clockwise until the collar lip fits snugly against locking ring.
4. Insert Metal Combination Tool (part #3-17-7) into collar and rotate clockwise until collar is firmly seated.